<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>BPD Limited &#124; Electrical Installation, Inspection &#38; Testing &#124; PAT Testing - Emergency Light Testing - Fixed Wire Electrical Inspection and Test &#187; News</title>
	<atom:link href="http://www.bpd-ltd.com/index.php/category/news/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.bpd-ltd.com</link>
	<description></description>
	<lastBuildDate>Sun, 29 Jan 2012 16:21:09 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
		<item>
		<title>Rogues Gallery</title>
		<link>http://www.bpd-ltd.com/index.php/2009/12/rogues-gallery/</link>
		<comments>http://www.bpd-ltd.com/index.php/2009/12/rogues-gallery/#comments</comments>
		<pubDate>Sun, 13 Dec 2009 23:15:03 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.bpd-ltd.com/?p=250</guid>
		<description><![CDATA[  At the request of our engineers and customers alike we will be using this space to show some of the many faults found whilst carrying out our day to day work.   This picture does not do the story justice. The copper wire has become so hot it has melted because of a loose [...]]]></description>
			<content:encoded><![CDATA[<div class="mceTemp"> </div>
<p>At the request of our engineers and customers alike we will be using this space to show some of the many faults found whilst carrying out our day to day work.</p>
<div class="mceTemp"> </div>
<div class="mceTemp"><img class="size-thumbnail wp-image-252" title="Loose Connection" src="http://www.bpd-ltd.com/wp-content/uploads/2009/12/Loose-Connection-150x150.jpg" alt="Loose Connection" width="140" height="123" /></div>
<dl id="attachment_252" class="wp-caption alignleft" style="width: 596px; height: 131px;">
<dt class="wp-caption-dt" style="text-align: left;"><span style="background-color: #f3f3f3;">This picture does not do the story justice. The copper wire has become so hot it has melted because of a loose connection and has also melted the insulation. In addition to this to the left of the yellow tape you can see that the insulation has been damaged. This is due to the action of the switch it was fitted to, which also meant that as you opened the switch to look at the problem with the wire, two metal prongs were exposed and live presenting a very real danger to the electrician.</span> </dt>
</dl>
<div class="mceTemp"> </div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div class="mceTemp">
<div class="mceTemp"> </div>
<div class="mceTemp"> </div>
<div class="mceTemp">
<div class="mceTemp"> </div>
</div>
<div class="mceTemp"><img class="size-thumbnail wp-image-254" title="Junction Box" src="http://www.bpd-ltd.com/wp-content/uploads/2009/12/Junction-Box1-150x150.jpg" alt="An inside/outside junction box" width="150" height="150" /> </div>
<div class="mceTemp">
<div class="mceTemp">
<dl id="attachment_254" class="wp-caption alignleft" style="width: 591px; height: 77px;">
<dt style="text-align: left;"><span style="background-color: #f3f3f3;">This junction box is not suitable for use outside of the home as it is not waterproof. However as you see the domestic customer considered that filling it with childrens modeling clay rendered it waterproof.</span></dt>
<dt class="wp-caption-dt" style="text-align: left;"> </dt>
</dl>
</div>
</div>
<div class="mceTemp"> </div>
<div class="mceTemp"> </div>
<div class="mceTemp"> </div>
<div class="mceTemp"> </div>
<div class="mceTemp"> </div>
<div class="mceTemp"> </div>
<div class="mceTemp"><a href="http://www.bpd-ltd.com/wp-content/uploads/2009/12/278.jpg"><img class="alignleft size-medium wp-image-1134" title="All tied up in a bow for christmas" src="http://www.bpd-ltd.com/wp-content/uploads/2009/12/278-225x300.jpg" alt="" width="225" height="300" /></a></div>
<div class="mceTemp"> </div>
<div class="mceTemp"> Chunks of insulation missing and all tied in a bow for christmas. Dont know what the installer was thinking. At the top of the board there are three holes where he tried and failed to enter the panel. Behind all the tape there are even more problems AND the earth tag has not been tied to the earth bar so he didn&#8217;t even make sure covered himself if it developed into a fault.</div>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.bpd-ltd.com/index.php/2009/12/rogues-gallery/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Could your electrics benefit from a free health check?</title>
		<link>http://www.bpd-ltd.com/index.php/2009/10/could-your-electrics-benefit-from-a-free-health-check/</link>
		<comments>http://www.bpd-ltd.com/index.php/2009/10/could-your-electrics-benefit-from-a-free-health-check/#comments</comments>
		<pubDate>Tue, 27 Oct 2009 22:57:17 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.bpd-ltd.com/?p=243</guid>
		<description><![CDATA[We are offering a free visual inspection of your electrical installation....no strings]]></description>
			<content:encoded><![CDATA[<p>It&#8217;s always a good idea to accept free advice when offered. How you use this advice can be beneficial to the continued health and safety of your employees and customers.</p>
<p>We are offering a free visual inspection of your electrical installation. We won&#8217;t turn anything off and will do our best to keep disruption of your day to day business to a minimum whilst on your premises. If we feel you require it, we will offer free advice on how to tackle any specific problems we have found and advise you on your legal responsibilities with regards to your electrical installation.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.bpd-ltd.com/index.php/2009/10/could-your-electrics-benefit-from-a-free-health-check/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Why PAT testing?</title>
		<link>http://www.bpd-ltd.com/index.php/2009/09/why-pat-testing/</link>
		<comments>http://www.bpd-ltd.com/index.php/2009/09/why-pat-testing/#comments</comments>
		<pubDate>Sun, 13 Sep 2009 21:19:41 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.bpd-ltd.com/?p=214</guid>
		<description><![CDATA[We are often asked, 'Do we really need to PAT test?'....]]></description>
			<content:encoded><![CDATA[<div class="mceTemp">
<div class="mceTemp">
<div class="mceTemp">

<a href='http://www.bpd-ltd.com/index.php/2009/09/why-pat-testing/pat-1-3/' title='Fire hazard.'><img width="150" height="150" src="http://www.bpd-ltd.com/wp-content/uploads/2009/09/PAT-13-150x150.jpg" class="attachment-thumbnail" alt="A 1A wire connected via a connector to a 13A plug." title="Fire hazard." /></a>
<a href='http://www.bpd-ltd.com/index.php/2009/09/why-pat-testing/pat-2-3/' title='Shock hazard.'><img width="150" height="150" src="http://www.bpd-ltd.com/wp-content/uploads/2009/09/PAT-22-150x150.jpg" class="attachment-thumbnail" alt="This electric shock hazard was also within 3M of a swimming pool." title="Shock hazard." /></a>
<a href='http://www.bpd-ltd.com/index.php/2009/09/why-pat-testing/pat-3-2/' title='Fire hazard.'><img width="150" height="150" src="http://www.bpd-ltd.com/wp-content/uploads/2009/09/PAT-31-150x150.jpg" class="attachment-thumbnail" alt="This cable is too small for a 13A fuse." title="Fire hazard." /></a>
<a href='http://www.bpd-ltd.com/index.php/2009/09/why-pat-testing/pat-4-2/' title='Electric shock hazard.'><img width="150" height="150" src="http://www.bpd-ltd.com/wp-content/uploads/2009/09/PAT-41-150x150.jpg" class="attachment-thumbnail" alt="This cable damage can develop into an electric shock hazard (see later pictures)." title="Electric shock hazard." /></a>
<a href='http://www.bpd-ltd.com/index.php/2009/09/why-pat-testing/pat-5-2/' title='Electric shock hazard.'><img width="150" height="150" src="http://www.bpd-ltd.com/wp-content/uploads/2009/09/PAT-51-150x150.jpg" class="attachment-thumbnail" alt="This fault can develop into a shock or fire hazard." title="Electric shock hazard." /></a>
<a href='http://www.bpd-ltd.com/index.php/2009/09/why-pat-testing/pat-9-2/' title='Electric shock hazard.'><img width="150" height="150" src="http://www.bpd-ltd.com/wp-content/uploads/2009/09/PAT-91-150x150.jpg" class="attachment-thumbnail" alt="This cable has worn through to reveal the copper strands." title="Electric shock hazard." /></a>
</div>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.bpd-ltd.com/index.php/2009/09/why-pat-testing/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Why thermal imaging?</title>
		<link>http://www.bpd-ltd.com/index.php/2009/06/why-thermal-imaging/</link>
		<comments>http://www.bpd-ltd.com/index.php/2009/06/why-thermal-imaging/#comments</comments>
		<pubDate>Thu, 25 Jun 2009 20:08:21 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.bpd-ltd.com/?p=133</guid>
		<description><![CDATA[Thermal imaging is used by many of our industrial customers in regular maintenance programmes....]]></description>
			<content:encoded><![CDATA[<p>&nbsp;</p>
<p class="MsoNormal" style="mso-pagination: none;"><span style="font-family: Arial; font-size: 12pt; mso-default-font-family: Arial; mso-ascii-font-family: Arial; mso-latin-font-family: Arial; mso-greek-font-family: Arial; mso-cyrillic-font-family: Arial; mso-hebrew-font-family: Arial; mso-arabic-font-family: Arial; mso-latinext-font-family: Arial; language: en-GB; mso-ansi-language: en-GB;" lang="en-GB">Thermal imaging is a relatively new process to the electrical sector and is an excellent way of looking for potential </span><span style="font-family: Arial; font-size: 12pt; mso-default-font-family: Arial; mso-ascii-font-family: Arial; mso-latin-font-family: Arial; mso-greek-font-family: Arial; mso-cyrillic-font-family: Arial; mso-hebrew-font-family: Arial; mso-arabic-font-family: Arial; mso-latinext-font-family: Arial; language: en-GB; mso-ansi-language: en-GB;" lang="en-GB">problems as they are developing. It does not involve the turning off of any </span><span style="font-family: Arial; font-size: 12pt; mso-default-font-family: Arial; mso-ascii-font-family: Arial; mso-latin-font-family: Arial; mso-greek-font-family: Arial; mso-cyrillic-font-family: Arial; mso-hebrew-font-family: Arial; mso-arabic-font-family: Arial; mso-latinext-font-family: Arial; language: en-GB; mso-ansi-language: en-GB;" lang="en-GB">machinery or power and therefore it will not lose you any valuable production time. </span></p>
<p class="MsoNormal" style="mso-pagination: none;"><span style="font-family: Arial; font-size: 12pt; mso-default-font-family: Arial; mso-ascii-font-family: Arial; mso-latin-font-family: Arial; mso-greek-font-family: Arial; mso-cyrillic-font-family: Arial; mso-hebrew-font-family: Arial; mso-arabic-font-family: Arial; mso-latinext-font-family: Arial; language: en-GB; mso-ansi-language: en-GB;" lang="en-GB">A special camera is used to take a thermal image and a photograph of your </span><span style="font-family: Arial; font-size: 12pt; mso-default-font-family: Arial; mso-ascii-font-family: Arial; mso-latin-font-family: Arial; mso-greek-font-family: Arial; mso-cyrillic-font-family: Arial; mso-hebrew-font-family: Arial; mso-arabic-font-family: Arial; mso-latinext-font-family: Arial; language: en-GB; mso-ansi-language: en-GB;" lang="en-GB">machines electrical components. Hot spots on the thermal image identify where there are potential problems such as loose connections and overloading, even faulty motors may be found, maintenance procedures may then be put in place to remedy the fault rather than an expensive breakdown as the fault develops. </span></p>
<p class="MsoNormal" style="mso-pagination: none;"><span style="font-family: Arial; font-size: 12pt; mso-default-font-family: Arial; mso-ascii-font-family: Arial; mso-latin-font-family: Arial; mso-greek-font-family: Arial; mso-cyrillic-font-family: Arial; mso-hebrew-font-family: Arial; mso-arabic-font-family: Arial; mso-latinext-font-family: Arial; language: en-GB; mso-ansi-language: en-GB;" lang="en-GB">Thermal </span><span style="font-family: Arial; font-size: 12pt; mso-default-font-family: Arial; mso-ascii-font-family: Arial; mso-latin-font-family: Arial; mso-greek-font-family: Arial; mso-cyrillic-font-family: Arial; mso-hebrew-font-family: Arial; mso-arabic-font-family: Arial; mso-latinext-font-family: Arial; language: en-GB; mso-ansi-language: en-GB;" lang="en-GB">imaging is used by many of our industrial customers in regular maintenance </span><span style="font-family: Arial; font-size: 12pt; mso-default-font-family: Arial; mso-ascii-font-family: Arial; mso-latin-font-family: Arial; mso-greek-font-family: Arial; mso-cyrillic-font-family: Arial; mso-hebrew-font-family: Arial; mso-arabic-font-family: Arial; mso-latinext-font-family: Arial; language: en-GB; mso-ansi-language: en-GB;" lang="en-GB">programmes, so if you have any industrial customers who are not using a service like this but are always complaining about down time through machine breakdowns you now have an answer for them. Thermal imaging.</span></p>
<p class="MsoNormal" style="mso-pagination: none;"><span style="language: en-GB;" lang="en-GB"> </span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.bpd-ltd.com/index.php/2009/06/why-thermal-imaging/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>